7000 and 7001APL

7000 and 7001APL

Description

Panel mount digital thermometer user selectable for type via external dip switch with front panel touch switch for selecting °C or °F. Features bright red LED display and a 1/8 DIN plastic housing. Model 7001APL has Min/Max switch for display of Min/Max temperatures. Available for types. J, K, T, E, N, R, S, DIN-T and DIN J. Ambient range-10 to 60°C. 115/230V AC operation.
  • CMOS microcomputer design
  • Cold junction compensation
  • T/c calibration for types-k,j,t,e,n,r,din t,din j
  • T/c type, resolution and unit default select by dip switch
  • Wide temperature ranges
  • Error indicators
  • Front panel °C/°F selectable
  • 1°C/0.1°C resolution selectable
  • Min/max display
  • 0.56 led display
  • Easy to install, metal mounting bracket
  • Wide operation temperature
  • High accuracy and low cost

Specifications

  •  RangeResolutionAccuracy
    Temp °C, Type K-129.0 to 1320.0°C0.1°C±0.05% ±0.7°C
    Temp °C, Type K-129 to 1320°C1°C±0.05% ±1°C
    Temp °F, Type K-200.0 to 1999.0°F0.2°F±0.05% ±1.4°F
    Temp °F, Type K-200 to 2408°F1°F±0.05% ±1.4°F
    Temp °C , Type J-204.0 to 900.0°C0.1°C±0.05% ±0.7°C
    Temp °C , Type J-204 to 900°C1°C±0.05% ±1°C
    Temp °C , Type J-335.0 to 1652.0°F0.2°F±0.05% ±1.4°F
    Temp °C , Type J-335 to 1652°F1°F±0.05% ±1.4°F
    Temp °C, Type T-133.0 to 400.0°C0.1°C±0.05% ±0.7°C
    Temp °C, Type T-133 to 400°C1°C±0.05% ±1°C
    Temp °F, Type T-207.0 to 752.0°F0.2°F±0.05% ±1.4°F
    Temp °F, Type T-207 to 752°F1°F±0.05% ±1.4°F
    Temp °C, Type E-210.0 to 700.0°C0.1°C±0.05% ±0.7°C
    Temp °C, Type E-210 to 700°C1°C±0.05% ±1°C
    Temp °F, Type E-350.0 to 1292.0°F0.2°F±0.05% ±1.4°F
    Temp °F, Type E-350 to 1292°F1°F±0.05% ±1.4°F
    Temp °C, Type N-162.0 to 1300.0°C0.1°C±0.05% ±0.7°C
    Temp °C, Type N-240 to 1300°C1°C±0.05% ±1°C
    Temp °F, Type N-260.0 to 1999.8°F0.2°F±0.05% ±1.4°F
    Temp °F, Type N-413 to 2372°F1°F±0.05% ±1.4°F
    Temp °C, Type R0 to 1760°C1°C±0.05% ±2°C
    Temp °F, Type R32 to 3200°F1°F±0.05% ±4°F
    Temp °C, Type S95 to 1760°C1°C±0.05% ±2°C
    Temp °F, Type S203 to 3200°F1°F±0.05% ±4°F
    Temp °C, Type DIN T-108.0 to 610.0°C0.1°C±0.05% ±1.7°C
    Temp °C, Type DIN T-108 to 610°C1°C±0.05% ±2°C
    Temp °F, Type DIN T-162.0 to 1130.0°F0.2°F±0.05% ±3.2°F
    Temp °F, Type DIN T-162 to 1130°F1°F±0.05% ±3.2°F
    Temp °C, Type DIN J-182.0 to 900.0°C0.1°C±0.05% ±1.7°C
    Temp °C, Type DIN J-182 to 610°C1°C±0.05% ±2°C
    Temp °F, Type DIN J-296.0 to 1652.0°F0.2°F±0.05% ±3.2°F
    Temp °F, Type DIN J-296 to 1652°F1°F±0.05% ±3.2°F
  • General

    • Cold junction compensation: 0.03°C / 0.03°F
    • Ambient temperature: -10 to 60°C
    • Rated accuracy: 18 to 28°C
    • Temperature coefficient (outside of 10 to 28°c): 40 ppm/°C typical
    • Common mode noise rejection: 120 db min
    • Normal mode rejection ratio: Over 80 db at 50/60 hz
    • Input impedance: 100m ohm min
    • Lead resistance effect: Less than 5 uv for 1k ohms of lead resistance
    • Display: 0.56 high LED display
    • Annuciators: C,f
      min, max(for model 7001apl only)
    • Power: 115 VAC,230 VAC ¡à10%, 50/60hz
    • Power consumption: 3.5va
    • Weight: 0.34 kgs
    • Dimensions: 99 x 48 x 104 mm
      99mm behind mounting panel

Share this product