Browse through the listed products below. Jenco product specialists are available via phone or email. Contact Jenco for questions or to help you choose. |
|
|
|
|
|
|
|
|
691N
Popular!
|
0.00~14.00 pH |
0.01pH |
± 0.02 pH ± 1 LSD |
Transmitter
|
|
| |
|
Description:1/8 DIN panel mount pH transmitter with calibration by potentiometers. Has a manual temperature control knob and normal transmitter output of 4-20 mA output for 0-14 pH range or in expanded mode 4-2mA can be for any 2 pH units from 0 to 14 pH. Features a large bright red LED display. Connectors are a BNC pH input and spade lug screw type connector block. 115/230V AC. |
|
|
|
|
|
|
|
|
|
692
|
0.00~14.00 pH |
0.01pH |
± 0.02 pH ± 1 LSD |
Transmitter
|
|
| |
|
Description:1/8 DIN panel mount pH transmitter with 4-20 mA output and calibration by potentiometers. ATC temperature control uses a Pt-100 or simulation resistor. Features a large LCD display and uses a BNC input and spade lug screw type connector block |
|
|
|
|
|
|
|
693pH
|
0 to 14.00 pH |
N/A |
0.02pH ± 1 digit |
Transmitter
|
|
| |
|
Description:2-wire 4-20 mA pH transmitter in a sealed NEMA-4 enclosure powered by 11 to 80 Volts DC. Span is fixed 0-14 pH. Connectors are BNC and tinned leads for 3-K Balco ATC sensor or simulation resistor. |
|
|
|
|
|
|
|
695pH
|
0 to 14.00 pH |
0.01 pH |
0.02pH ± 1 digit |
Transmitter
|
|
| |
|
Description:2-wire 4-20 mA pH transmitter in a sealed NEMA-4 enclosure with an LCD display powered by 11 to 80 Volts DC. Span is selectable any 1 to 14 pH unit via internal dip switch. Connections are BNC for pH and tinned leads for 3-K Balco ATC sensor or simulation resistor. |
|
|
|
|
|
|
|
693ORP
|
-700 ~ 700 mV |
N/A |
1 mV ± 1 digit |
Transmitter
|
|
| |
|
Description:2-wire 4-20 mA ORP transmitter in a sealed NEMA-4 enclosure powered by 11 to 80 Volts DC. Span is fixed 1400 mV span. Connections are BNC for mV/ORP. |
|
|
|
|
|
|
|
695ORP
|
-700 ~ 700 mV |
1 mV |
1 mV ± 1 digit |
Transmitter
|
|
| |
|
Description: 2-wire 4-20 mA ORP transmitter in a sealed NEMA-4 enclosure with an LCD display powered by 11 to 80 Volts DC. Span is selectable any 100 to 1400 mV unit by dipswitch. Connections are BNC for ORP. |
|
|
|
|
|
|
|
392
|
0 uS/cm to 199.9 mS/cm (over 6 ranges) |
0.01 uS/cm to 0.1 mS/cm (over 6 ranges) |
± 1% of Span, ± 1 digit |
Transmitter
|
|
| |
|
Description:Conductivity Transmitter, panel mount, 1/8 DIN aluminum package, K=1.0 cell constant, isolated 4-20 mA analog transmitter current output, ATC is 10K thermistor for 5 to 55°C. Connections are to terminal blocks via spade lug connectors. 115/230V AC powered. |
|
|
|
|
|
|
|
392SBC
|
0 to 5.0 mS/cm |
0.01 mS/cm |
± 1% of Span, ± 1 digit |
Transmitter
|
|
| |
|
|
0 to 15.0 mS/cm |
0.01 mS/cm |
± 1% of Span, ± 1 digit |
|
| |
|
Description:Conductivity Transmitter, panel mount, 1/8 DIN aluminum case, K=1.0 cell constant, isolated 4-20 mA output for 0 to 5.0 mS range, 0 mA = 0 mS, 20 mA = 5.0 mS. Isolated 4- 30 mA transmitter output for 0 to 15.0 mS range, 0 mA = 0 mS, each 5/16 mS thereafter equals 1.0 mA additionally. ATC is 10K thermistor, 5 to 55°. Connections are to terminal blocks via spade lug connectors. 115/230V AC powered. |
|
|
|
|
|
|
|
791 and 791L
|
-50 to 1250 Centigrade |
1 Centigrade |
± 2.6 Centigrade |
Transmitter
|
|
| |
|
|
-58 to 1999 Fahrenheit |
1 Fahrenheit |
± 4.7 Fahrenheit |
|
| |
|
|
-150 to 760 Centigrade |
1 Centigrade |
plusmn;2.0Centigrade |
|
| |
|
|
-238 to 1400 Fahrenheit |
1 Fahrenheit |
± 3.6 Fahrenheit |
|
| |
|
|
-150 to 400 Centigrade |
1 Centigrade |
± 2.0 Centigrade |
|
| |
|
|
-238 to 752 Fahrenheit |
1 Fahrenheit |
± 3.6 Fahrenheit |
|
| |
|
|
-95 to 850 Centigrade |
1 Centigrade |
± 2.6 Centigrade |
|
| |
|
|
-139 to 1562 Fahrenheit |
1 Fahrenheit |
± 4.7 Fahrenheit |
|
| |
|
|
-150.0 to 199.9Centigrade |
0.1 Centigrade |
± 0.5 Centigrade |
|
| |
|
|
-50 to 850 Centigrade |
1 Centigrade |
± 0.2 Centigrade |
|
| |
|
Description:Panel mount digital temperature transmitter with 4- 20 mA current output that allows the 791 to drive any loop powered process indicator or recorder. Current output has expanded or normal switch for user adjustable center point and span control for temperature to 4-20 mA output and features a LCD display & 1/8 DIN Aluminum case. Types. J, K, T, 3-wire Pt-100 RTD, specify °C or °F. Ambient range 0 to 40°C. 115 / 230V AC operation. |