Browse through the listed products below. Jenco product specialists are available via phone or email. Contact Jenco for questions or to help you choose. |
|
|
|
|
|
|
|
|
3671N
Popular!
|
0~14.0 |
0.1 |
0.1 ± 1digit |
Controller
|
|
| |
|
|
-1990~1990 mV |
10 |
± 0.1% ± 1 digit |
|
| |
|
|
0 ~ 100 °C |
1 |
1 ± 1 digit |
|
| |
|
Description:1/8 DIN panel mount pH/ORP controller with dual SPDT Hi/Lo relays, manual set points and calibration are via potentiometers. Features a voltage/recorder output and an internal pH/ORP select switch. Display is a large bright red LED. Connectors are a BNC input and spade lug screw type connector block. Meter requires a Pt-100 ATC or a simulation resistor for temperature. Power115/230A AC. |
|
|
|
|
|
|
|
3675
Popular!
|
0~14.00 |
0.01 |
± 0.01 |
Controller
|
|
| |
|
|
-1999~1999 mV |
1 |
± 0.1% |
|
| |
|
Description:1/4 DIN panel mount pH/ORP controller/transmitter with dual SPDT Hi/Lo relays, manual set points and calibration are via potentiometers. Features a 4-20 mA current output and has an external pH/ORP select switch. Display is a large LCD. Connectors are a BNC and spade lug screw type connector blocks. Meter requires a Pt-100 ATC or a simulation resistor for temperature. Power 115/230V AC. |
|
|
|
|
|
|
|
3676
|
0~14.00 |
0.01 |
± 0.01 |
Controller
|
|
| |
|
|
-1999~1999 mV |
1 |
± 0.1% |
|
| |
|
Description:1/4 DIN panel mount pH/ORP controller/transmitter with dual SPDT Hi/Lo relays, manual set points and calibration are via potentiometers. Features a 4-20 mA current output and has an external pH/ORP select switch. Display is a large bright red LED display. Connectors are a BNC input and spade lug screw type connector blocks. Meter requires a Pt-100 ATC or temp. simulation resistor. Power 115/230V AC. |
|
|
|
|
|
|
|
3677
|
0.00~14.00 pH |
0.01 pH |
0.1% ± 1 LSD |
Controller
|
|
| |
|
|
-1999~1999 mV |
1 mV |
0.1% ± 1 LSD |
|
| |
|
Description:1/8 DIN vertical configuration panel mount pH/ORP controller/transmitter with dual SPDT Hi/Lo relays, manual set points and calibration are via potentiometers. Features a 4-20 mA current output and has an external pH/ORP select switch. Display is a large LCD. Connectors are a BNC input and spade lug screw type connector blocks. Meter requires a Pt-100 ATC or temp. simulation resistor. Power 115/230V AC. |
|
|
|
|
|
|
|
3679N
New!
|
0.00~14.00 pH |
0.01 pH |
0.1% ± 1 LSD |
Controller
|
|
| |
|
|
-1999~1999 mV |
1 mV |
0.05% ± 1 LSD |
|
| |
|
Description:1/4 DIN panel mount pH/ORP controller/transmitter in a waterproof IP-65 enclosure. Features, LCD display, dual SPDT Hi/Lo relays, manual set point adjust and pH calibration via potentiometers. For ORP there is a Zero Adjustment and pH/ORP is selectable via a shorting plug. Output is 4-20 mA current type. Connectors are a spade lug circular connector for pH+. All other connections are tinned leads to terminal blocks. Temperature compensation is a Pt-100 ATC or simulation resistor. Power 115/230V AC. |
|
|
|
|
|
|
|
6303C
|
-2.00 ~ 16.00 pH |
0.01 pH |
± 0.01 pH |
Controller
|
|
| |
|
|
-1999 ~ 1999mV |
1 mV |
± 0.1% |
|
| |
|
|
-3.0 ~ 115.0 °C |
0.1 °C |
± 0.2 °C |
|
| |
|
Description:1/4 DIN panel mount pH controller, microprocessor based with membrane type keypad and password protection. Meter has a programmable, reversible and isolated 4- 20 mA current output and dual SPDT relays. Connectors are a BNC and spade lug terminal blocks. ATC is a 10K thermistor or simulation resistor. Features a NEMA-4 type bezel for watertight seals against mounting panels. 115/230V AC. |
|
|
|
|
|
|
|
6303P
|
-2.00 ~ 16.00 pH |
0.01 pH |
± 0.01 pH |
Controller
|
|
| |
|
|
-1999 ~ 1999mV |
1 mV |
± 0.1% |
|
| |
|
|
-3.0 ~ 115.0 °C |
0.1 °C |
± 0.2 °C |
|
| |
|
Description:1/4 DIN panel mount pH controller microprocessor based with membrane type keypad and password protection. Meter has a programmable, reversible and isolated pulse frequency output and dual SPDT relays. Connectors are BNC and spade lug terminal blocks. ATC is a 10K thermistor or simulation resistor. Features a NEMA-4 type bezel for watertight seals against mounting panels. 115/230V AC. |
|
|
|
|
|
|
|
6308OT
New!
|
-2500~2500mV |
1mV |
±0.04% FS ± 1 |
Controller
|
|
| |
|
|
-6499~6499mV |
1mV |
±0.02% FS ± 1 |
|
| |
|
|
-10.0 ~o 120 °C |
0.1°C |
± 0.3°C |
|
| |
|
Description:Description:ORP analyzer, 1/4 DIN panel mount IP-65 case, Features 4 for fully programmable relays and 1 for temperature. RS-485 interface, password protected with individual ID's. 4-20 mA analog output is fully programmable, assignable & reversible. Graphical display. Tinned lead connectors. CE Approved. |
|
|
|
|
|
|
|
6503
|
-2.00 to 16.00 pH |
0.01 pH |
± 0.01pH ± 1 digit |
Controller
|
|
| |
|
|
-1999 ~ 1999 mV |
1 mV |
±0.1% ± 1 digit |
|
| |
|
|
0 ~ 115 °C |
0.1 °C |
± 0.2 °C ± 1 digit |
|
| |
|
Description:1/4 DIN panel mount ORP controller/transmitter, microprocessor based, password protected with membrane keypad. LCD displays ORP or pH and temp. Meter has dual SPDT Hi/Lo relays, with programmable hysteresis and a reversible, isolated and programmable 4-20 mA output. Connectors are dual BNC for pH/ORP and spade lug type. ATC is 10K thermistor or simulation resistor. Power 115 / 230V AC. |
|
|
|
|
|
|
|
6715
|
0.0~14.0 pH |
0.01 pH |
0.2% ± 1 LSD |
Controller
|
|
| |
|
|
-1999 ~ 1999mV |
1 mV |
0.05% ± 1 digit |
|
| |
|
Description:Wall mounted controller available in 3 models. Model 6715 controls pH & ORP and is intended for Aquarium use, model 6715-01 controls pH & ORP and is for Pool & Spa use. Model 6715-pH is intended for Pools and controls only pH. Units have two energized 115 volt AC, 3-prong U.S. standard electrical sockets for plugging in dosing pumps. Connectors are BNC for pH/ORP and banana plugs for the 10K ATC. |