pH meters, conductivity meters, dissolved oxygen meters, ORP meters, ion meters, TDS meters for field, laboratory and industrial applications  
   
Products  >  Benchtop  >  ORP

Browse through the listed products below. Jenco product specialists are available via phone or email. Contact Jenco for questions or to help you choose.
Model Range Resolution Accuracy Type
1671 -2.00 ~ 16.00 0.01 pH
0.1% ± 1 digit Benchtop
-999 ~ 999 mV 1 mV
0.1% ± 1 digit
0.0 us/cm ~ 199.9 ms/cm (over 5 ranges) 0.01 us/cm ~ 0.1 ms/cm (over 5 ranges)
± 0.1% F,S., ± 0.2% reading
0.0 ~ 100 °C 0.1 °C
± 0.5°C ± 1 digit
Description:pH/mV/Conductivity/Temperature benchtop meter with dual LCD displays for conductivity and pH/mV/temp. Has dual analog voltage outputs for pH/mV and conductivity. Connectors are BNC, Jenco 4-Pin Jenco screw type connector for 10K thermistor ATC. Features cell adjust and 4.01/7.00/10.01 buffer select. Built in transformer for 115/230 VAC operation or battery powered via 6 AA batteries.
Model Range Resolution Accuracy Type
3601 0.00~14.00 pH 0.01 pH
0.02% ± 1 LSD Benchtop
-1999~1999 mV 1 mV
0.05% ± 1 LSD
Description:pH/ORP controller with dual SPDT Hi/Lo relays, manual set points via potentiometers and calibration via potentiometers with a voltage/recorder output and has an internal pH/ORP select switch and large bright red LED display uses a BNC input and spade lug screw type connector block requires a Pt-100 ATC or a simulation resistor for temperature.
Model Range Resolution Accuracy Type
6072 -2.00 ~ 16.00 pH 0.01pH
± 0.1% Benchtop
-999 ~ 999 mV 1 mV
± 0.1% ± 1 digit
0 ~ 99.9 °C 0.1 °C
±0.5°C
Description:pH/mV/Temp. dual purpose bench and portable meter, microprocessor based with build in tabletop stand, LCD digital display and ATC. Features include a voltage recorder output, and both Jenco 4-Pin, 3-in-1 and BNC input connectors, electrode reference input pin and Jenco screw type ATC input. AC/DC Powered.
Model Range Resolution Accuracy Type
6091N 2.00 to 16.00 0.01
±0.01 ± 1 digit Benchtop
-999 to 999 1
0.1% ± 1 digit
0 to 99.9 °C 0.1
±0.5 ± 1 digit
Description:pH/mV/Temp. benchtop meter, microprocessor based with built in paper printer with time date stamp and optional RS-232C computer interface. Features a voltage recorder output and dual LCD digital displays for time/date and pH/mV/ temp. Connectors are a Jenco 4-Pin, BNC and a reference pin connector. AC/DC Powered with built in 115/230 volt transformer.
Model Range Resolution Accuracy Type
6171 Popular! -2.00 ~ 16.00 pH 0.01pH
± 0.1 % ± 1 digit Benchtop
-1999 ~ 1999 mV 1.0 mV
± 0.1 % ± 1 digit
5.0 to 125.0 °C 0.1 °C
± 0.5 °C
Description:pH/mV/Temp. bench meter, microprocessor based with RS-232C IBM compatible computer interface with dual pH/mV and temperature LCD digital displays, BNC input and ATC probe uses an 8-pin DIN type input. AC/DC Powered.
Model Range Resolution Accuracy Type
6171L -2.00 ~ 16.00 pH 0.01pH
± 0.1 % ± 1 digit Benchtop
-1999 ~ 1999 mV 1.0 mV
± 0.1 % ± 1 digit
5.0 to 125.0 °C 0.1 °C
± 0.5 °C
Description:pH/mV/Temp. bench meter, microprocessor based with dual pH/mV and temperature LCD digital displays, BNC input and ATC probe uses an 8-pin DIN type input. AC/DC Powered.
Model Range Resolution Accuracy Type
6173 New! Popular! -2.00 to 20.00 pH 0.01pH
± 0.01 pH ± 1 LSD Benchtop
-2000 to 2000 mV 1.0 mV
±0.05% mV of rdg(range) ± 1 LSD
-10.0 to 120.0 °C 0.1 °C
±0.5 °C ± 1 LSD
Description:pH/mV/Temp benchtop meter with an extra large LCD display for ease of use. Features a splash proof and rugged case ideal for schools and universities. Features EEF, Electrode Efficiency Function, multiple buffers 4.00, 4.01, 6.86, 7.00, 9.18 & 10.0 and automatic slope, buffer and electrode offset recognition. Has power down memory backup and works on 6 AA batteries or 115/230 V AC adapters. CE Approved & ISO 9001 Certified.
Model Range Resolution Accuracy Type
6173R New! -2.00 to 20.00 pH 0.01pH
± 0.01 pH ± 1 LSD Benchtop
-2000 to 2000 mV 1.0 mV
±0.05% mV of rdg(range) ± 1 LSD
-10.0 to 120.0 °C 0.1 °C
±0.5 °C ± 1 LSD
Description:pH/mV/Temp benchtop meter with a very large LCD display for ease of use. Features a splash proof and rugged case ideal for schools and universities. Features EEF, Electrode Efficiency Function, multiple buffers 4.00, 4.01, 6.86, 7.00, 9.18 & 10.0 and automatic slope, buffer and electrode offset recognition. Has power down memory backup and works on 6 AA batteries or 115/230 V AC adapters. CE Approved & ISO 9001 Certified. RS-232C output.
Model Range Resolution Accuracy Type
6201 0 ~ 14.00 pH 0.01pH
± 0.1% Benchtop
-2047 ~ 2047 mV 1 mV
± 0.05
-409.5 ~ 409.5 Emv 0.1 mV
± 0.05%
-10 ~ 125 °C 1 °C
± 0.5
Description: pH/mV/Temp. bench meter, microprocessor based with red LED digital display and manual or Pt-100 ATC temperature compensation. Connectors are a BNC input, reference input pin and banana plug connectors for the ATC . Meter does not offer direct Ion concentration readout but requires data to be graphed and interpreted. AC Powered only built in transformer 115/230 volts.
Model Range Resolution Accuracy Type
6209 0 ~ 14.00 pH 0.01pH
± 0.1% Benchtop
-2047 ~ 2047 mV 1 mV
± 0.05
-409.5 ~ 409.5 Emv 0.1 mV
± 0.05%
1.0 ~ 995.0 conc. (over 6 ranges) 0.5 conc. ~ 5.0 conc. (over 6 ranges)
± 0.1%
-10 ~ 125 °C 1 °C
± 0.5
Description:pH/mV/Temp./ION bench meter, microprocessor based with direct Ion concentration readout, and red LED digital display. Temperature compensation is manual or Pt-100 ATC. Connectors are BNC input, reference pin input and banana plugs for ATC. AC Powered only built in transformer 115/230 volts.
Model Range Resolution Accuracy Type
6219 Popular! -2.000 ~ 16.000 pH 0.01 pH or 0.001 pH ( selectable )
± 0.1 % ± 1 digit Benchtop
-1999.9 ~ 1999.9 mV 1 mV or 0.1 mV ( selectable )
± 0.1 % ± 1 digit
0.00~119.8 conc.,
over 3 ranges
0.05~0.2 conc.,
over 3 ranges
± 2 LSD
5.0 to 125.0 °C 0.1 °C
± 0.5 °C
Description:pH/mV/Temp./ION bench meter, microprocessor based with direct Ion concentration readout and RS-232C IBM compatible computer interface. Features dual pH/mV/Ion and temperature LCD digital displays, uses a BNC input and 8-Pin DIN ATC connector. AC/DC Powered.
Model Range Resolution Accuracy Type
671P 0~14.00pH 0.01pH
± 0.1% ± 1 digit Benchtop
-1999 ~ 1999 mV 1 mV
± 0.1% ± 1 digit
0 ~ 100 °C 0.1 °C
± 0.5°C ± 1 digit
Description:pH/mV/Temp. benchtop meter with LCD digital display, voltage recorder output, Karl Fisher output and Pt-100 ATC or manual temperature compensation. Calibration is via knobs and potentiometer. Connectors are BNC or U.S. standard connector with reference pin and banana plugs for ATC and recorder. AC/DC Powered.
Model Range Resolution Accuracy Type
672P 0~14.00pH 0.01pH
± 0.01 ± 1 digit Benchtop
-1999 ~ 1999 mV 1 mV
± 0.1% ± 1 digit
0 ~ 100 °C 0.1 °C
± 0.5°C ± 1 digit
Description:pH/mV/Temp. dual purpose benchtop and portable meter with built in desktop stand with LCD digital display, voltage recorder output and Pt-100 ATC or manual temperature compensation. pH calibration is via knobs and potentiometer. Connectors are BNC, reference pin and banana plugs for ATC and recorder. AC/DC Powered.